The embedded active road weather sensor ARS31-UMB detects freezing temperatures independently from de-icing materials and is easy to maintain through its two parted housing.
The active road sensor ARS31 is installed flush with the road/runway surface and calculates the freezing temperature by means of active cooling and heating of the sensor surface. The freezing temperature measurement is independent of mixture. The two-section housing design allows the combined sensor/electronics unit to be removed for maintenance purposes at any time, in just a few minutes. In conjunction with interface converter 8160.UISO, the sensor can be built into new and existing UMB networks. Passive sensor IRS31 and active sensor ARS31 can be combined without difficulty, in fact this is recommended. The sensors are addressable and hence can be networked.
- reezing point
- ctive cooling and heating (Peltier element)
- Two part housing design allows easy maintenance/re-calibration, low energy consumption allows solar operation, freezing point determined independently from de-icing material
Advantages
- Replaceable sensor/electronics
- Simulation of critical surface conditions in the avery near future
- Mixture-independent measurement
- Analog outputs in combination with 8160.UDAC
General | |
Dimensions | Ø 120mm, height 50mm |
Weight | Approx. 900g |
Storage temperature | -40…80°C |
Protection type | IP68 |
Power supply | 24 VDC ±10% |
Connector | CAGE CLAMP, WAGO, (cross-section <0.5mm²) |
Operating temperature | -40…80°C |
Operating rel. humidity | 0…100% RH |
Power consumption | Approx. 30 W |
Interface | RS485, baud rate: 2,400…38,400 bit/s (default: 19,200), |
cable length | 50m |
Freezing point | |
Measuring range | -40 … 0 °C |
Unit | °C |
Accuracy | ±0.5°C RMS for freezing temperature > -15 °C, or ±1.5°C RMS for freezing temperature < -15 °C (with NaCI) |
Resolution | 0.1 |